Knowledge Centre

Fire Protection FAQs

Clear, practical guidance on the technical fire and life-safety disciplines we deliver, with dedicated information on FPSPs and NFPA 25.

Fire Sprinkler SystemsFire Detection & Alarm SystemsGaseous Fire Suppression SystemsFoam & Specialised Suppression SystemsHydrants & Hose ReelsFire Pumps & Water Storage TanksFire Extinguishers & SignagePassive Fire Protection & Fire DoorsSmoke Control & Electrical ServicesRisk ManagementEvacuation PlansFire Protection Systems Practitioners (FPSPs)NFPA 25

Important: These answers provide general information, not project-specific legal or professional advice. Requirements depend on the building, occupancy, approved design, applicable standard editions, local by-laws, insurer and the authority having jurisdiction.

01

Fire Sprinkler Systems

The standards, professional competence and project conditions governing sprinkler-system work.

Which requirements govern Fire Brand’s sprinkler-system work?

Fire Brand undertakes sprinkler work in accordance with the applicable edition of SANS 10287, the approved design and project specifications, applicable legal and local-authority requirements, manufacturer instructions, and any binding client or insurer conditions. Where NFPA standards or FM Global Property Loss Prevention Data Sheets form part of the approved design basis, those requirements and specified equipment approvals are also applied.

Is listing under a private Local Rulebook scheme always required for sprinkler work?

No. A privately administered technical or inspection scheme is not legislation, statutory professional registration or a statutory licence to practise. A particular insurer, client, policy or project may expressly require scheme listing, inspection or a clearance certificate, but that condition is specific to that engagement rather than a universal legal requirement.

What sprinkler services is Fire Brand competent to provide?

Within the relevant ECSA endorsements and the competence of assigned personnel, Fire Brand provides sprinkler design, installation, commissioning, inspection and maintenance under the professional oversight of an ECSA-registered Fire Protection Systems Practitioner. Each project remains subject to its approved design and applicable technical and contractual requirements.

Can Fire Brand install and maintain sprinkler pumps and water supplies?

Yes. Fire Brand can install, inspect, test, service and maintain sprinkler pump sets and associated water-based systems through appropriately competent personnel under FPSP oversight. Work is carried out against SANS 10287, the approved design, manufacturer instructions and any expressly applicable project or insurer condition.

What records does Fire Brand provide after sprinkler work?

Fire Brand provides the relevant service records, inspection and test results, and handover information for the agreed scope. The records identify the work performed, results, outstanding defects or limitations, and any corrective action required, and are issued to the client and other designated project parties where applicable.

02

Fire Detection & Alarm Systems

Automatic detection, manual alarm, notification, monitoring and cause-and-effect controls.

When is a fire detection and alarm system required?

The approved building design, occupancy and fire strategy determine whether automatic detection, manual alarm, voice alarm or monitoring is required. SANS 10400-T, SANS 10139, local by-laws, authority conditions and any approved rational design must be considered, using the editions formally adopted for the project.

Who may install or service a fire detection system?

Work should be performed by competent personnel holding the registrations required for the particular detection scope. The installer and commissioner must be able to demonstrate that the work follows the approved design and applicable standard.

What is a cause-and-effect matrix?

It records how each fire input must affect alarms, evacuation signals and interfaced equipment such as smoke control, lifts, access control, suppression and plant shutdowns. It should be approved, tested during commissioning and kept current.

Are alterations to a fire alarm loop permitted without approval?

Changes can affect coverage, loading, zoning, fault monitoring and system logic. They should therefore be designed, documented, commissioned and approved to the extent required by the original design basis and authority having jurisdiction.

What documentation should follow fire detection commissioning?

Typical records include approved and as-built drawings, device schedules, zoning information, cause-and-effect testing, battery and power calculations, commissioning results, user training, operating instructions and the applicable declaration or certificate.

03

Gaseous Fire Suppression Systems

Clean-agent and inert-gas systems for data rooms, electrical rooms and other critical risks.

When is gaseous suppression appropriate?

It is generally considered where rapid suppression is needed without water damage and where the protected enclosure can retain the design concentration. A competent risk and design assessment must confirm agent suitability, life-safety precautions and environmental restrictions under the applicable part of SANS 14520 or, where adopted as the project basis, NFPA 2001.

Must the protected room pass an enclosure integrity test?

Where the system relies on maintaining an extinguishing concentration, enclosure integrity must be verified using the method required by the approved design standard. Changes to doors, walls, ceilings, services or ventilation can require retesting.

What life-safety controls are required before agent discharge?

Requirements depend on the agent and design, but may include detection logic, pre-discharge alarms, time delay, abort or manual controls, warning signage, ventilation shutdown, pressure relief and safe evacuation provisions.

Can cylinders be replaced with a different agent or size?

Not without engineering review. Agent quantity, concentration, pressure, pipework, nozzles, room volume, temperature and approvals are interdependent, so substitutions require redesign, documentation and recommissioning.

What should be checked after changes inside a protected enclosure?

Review room volume, leakage, openings, ventilation, equipment layout, obstructions and occupancy. The detection and release sequence, agent calculations and enclosure integrity should be reassessed where the change can affect performance or safety.

04

Foam & Specialised Suppression Systems

Foam, water spray, kitchen, vehicle and hazard-specific fixed suppression systems.

When is foam protection required?

Foam may be selected for particular flammable-liquid and process hazards where the approved risk assessment and design standard require vapour suppression, control or extinguishment. The fuel, application method and foam compatibility must be established under the approved design basis, which may include SANS 10287, NFPA 11, NFPA 16 or an insurer standard.

May any foam concentrate be used in an existing system?

No. Concentrate type, proportioning equipment, discharge devices, listed approvals, fuel compatibility and environmental obligations must align. A change in concentrate can require engineering review, testing and authority or insurer acceptance.

Are environmental controls relevant to foam-system testing?

Yes. Test planning must consider containment, collection, disposal and restrictions applicable to the concentrate. Full discharge should not be undertaken without the necessary environmental and site controls.

How are kitchen and other pre-engineered systems regulated?

They must be designed, installed and maintained in accordance with the system listing, manufacturer instructions, approved risk and authority requirements, and the adopted standard. Depending on the hazard, that basis may include NFPA 17A and NFPA 96 for commercial cooking, NFPA 15 for water-spray systems or another listed pre-engineered-system standard.

What commissioning evidence is needed for specialised suppression?

Provide the approved design basis, calculations where applicable, equipment approvals, installation checks, functional and discharge test evidence, interface testing, operating instructions and the required completion documentation.

05

Hydrants & Hose Reels

Internal and external firefighting water points, reticulation and fire-brigade access.

Who determines the number and position of hydrants and hose reels?

The approved fire design and applicable standards determine coverage, spacing and location, subject to local fire-service and authority requirements. Relevant references can include SANS 10400-T, SANS 1128-1 and SANS 1128-2 for hydrant components and connections, SANS 543 for hose reels and SANS 10105-2 for their selection and use.

Must hydrant water flow and pressure be tested?

Yes, at the intervals and by the methods required by the approved design basis and maintenance standard. Results should be recorded and compared with the required performance so deterioration or supply problems are identified.

May a municipal supply be assumed to meet the fire demand?

No. Available flow, pressure, reliability and authority conditions must be established. Where the supply cannot meet the required demand or duration, dedicated storage and pumping may be necessary.

Can hose reels or hydrants be obstructed or used for general purposes?

Firefighting equipment and access routes must remain visible, accessible and ready for emergency use. Unauthorised use, obstruction, isolation or damage should be prevented and corrected promptly.

What records are needed after hydrant or hose-reel alterations?

Update the as-built layout and asset register, record pressure or flow testing and retain details of valves, pipework and equipment changed. Required inspections and authority or professional close-out should be completed.

06

Fire Pumps & Water Storage Tanks

Dedicated fire-water supplies, pump sets, controllers, valves and storage arrangements.

When is a dedicated fire pump and tank required?

They are required where the available supply cannot reliably provide the design flow, pressure or duration. The approved hydraulic design, SANS 10287, the adopted Local Rulebook and insurer or authority requirements determine capacity and arrangement; NFPA 20 and NFPA 22 may apply where expressly adopted for fire pumps and water-storage tanks.

May fire-water storage be used for domestic or process purposes?

Only where the approved design expressly permits it and safeguards the required fire reserve. Connections, levels and controls must prevent other uses from reducing the protected fire-water quantity.

How often must fire pumps be tested?

The applicable maintenance standard specifies routine running, alarm and performance-test frequencies. Tests should cover the required pump and controller functions, with readings trended against commissioning or acceptance data.

Does standby power remove the need for pump redundancy?

Not necessarily. Pump duty, redundancy, driver type and power arrangements form part of the approved design and risk strategy. They should not be changed without competent review and required approval.

What should happen if a fire pump or tank is impaired?

Treat the loss as a fire-protection impairment: notify responsible parties, assess the risk, apply required temporary precautions, expedite repair and document restoration and testing before closing the impairment.

07

Fire Extinguishers & Signage

Portable firefighting equipment, statutory identification and emergency information.

How are extinguisher types and quantities selected?

Selection must suit the fire classes, hazards, floor area, travel distance and occupancy. SANS 10400-T and SANS 10105-1 guide provision and selection, while the relevant product standard - such as SANS 1910, SANS 1567, SANS 1571 or SANS 1573 - applies to the extinguisher type specified.

Who may service portable fire extinguishers?

Servicing and reconditioning must be performed within the SANS 1475-1 framework by appropriately registered competent personnel operating through an approved organisation. SANS 1475-2 applies to reconditioned hose reels. Current registration and scope should be verified.

Is an extinguisher service label enough evidence?

The label is important but should be supported by an asset register and service documentation. The owner must also ensure correct location, accessibility, condition, suitability and timely correction of defects.

When must extinguishers be replaced or pressure tested?

The applicable standard, cylinder condition, service history and manufacturer requirements determine overhaul, pressure testing, rejection and replacement. Damaged, corroded, discharged or suspect equipment requires immediate competent assessment.

What makes fire-safety signage compliant?

Signs must use the required symbols, colours, sizes, visibility and positioning for their purpose. SANS 1186-1 provides the standard signs and general requirements, while SANS 10400-T, approved plans and local-authority requirements determine where fire and escape signage is needed.

08

Passive Fire Protection & Fire Doors

Compartmentation, fire stopping, fire-rated doors, shutters, curtains and penetration sealing.

Why is passive fire protection regulated?

Fire-rated walls, floors, doors and seals limit fire and smoke spread, protect escape routes and support structural and firefighting objectives. Their required ratings and locations come from SANS 10400-T and the approved fire design; relevant product and test references include SANS 1253 for fire-door assemblies and the SANS 10177 series for fire testing of building materials and elements.

May any product be used to seal a fire-rated penetration?

No. The complete tested or assessed system must suit the wall or floor, service type, opening, support and required fire rating. Mixing unapproved components or departing from the tested configuration can invalidate performance.

Can a fire door be modified for access control?

Only where the complete arrangement preserves the door’s fire rating, self-closing and latching operation, escape function and approved hardware. Cutting, drilling, glazing or adding hardware without suitable approval can invalidate the assembly.

Who should inspect passive fire protection?

A competent person familiar with the installed systems and approval criteria should inspect them. Specialist evidence may be required to assess concealed work, product substitutions, damaged systems or non-standard details.

What records should be retained for fire stopping and fire doors?

Keep approved drawings, product data and evidence of performance, installer records, location schedules, photographs, inspection results and any completion declarations. These records are essential when later penetrations or alterations occur.

09

Smoke Control & Electrical Services

Smoke control, pressurisation, controls, electrical supplies and interfaces with life-safety systems.

Is smoke control simply a normal ventilation system?

No. A smoke-control system is a life-safety system designed around fire scenarios, tenability, escape and firefighting objectives. Its design must follow SANS 10400-T, the approved rational fire strategy and the smoke-control standard adopted for the project, which may include the EN 12101 series for smoke and heat control systems.

Who may design a smoke-control system?

Design responsibility should be assigned to an appropriately competent person with the required fire and engineering competence for the scope. The authority having jurisdiction may require a rational design, supporting calculations and professional declarations.

Do fire-system electrical alterations require a Certificate of Compliance?

Where work forms part of an electrical installation governed by the Electrical Installation Regulations and SANS 10142-1, it must be performed by a legally registered electrical contractor and the required electrical Certificate of Compliance and test report must be issued for the relevant work.

Must smoke-control interfaces be tested together?

Yes. Individual component tests do not prove integrated performance. Commissioning should verify the approved cause-and-effect sequence across detection, fans, dampers, vents, doors, lifts, access control, power supplies and monitoring, with results recorded.

Can smoke-control equipment be isolated during normal building operation?

Any isolation or impairment must be controlled, authorised, recorded and restored promptly. The responsible person should assess the risk, notify affected parties and apply temporary precautions required by the site procedure, insurer or authority having jurisdiction.

10

Risk Management

Fire-risk assessments, compliance audits, insurance surveys and prioritised remediation.

Is a fire-risk assessment a compliance certificate?

No. It identifies hazards, evaluates controls and prioritises action; it does not approve the building or replace certificates, declarations and authority approvals required for particular systems.

When should a fire-risk assessment be reviewed?

Review it periodically and whenever material change occurs, including a new process, altered occupancy, storage changes, construction work, a fire incident, a significant system impairment or new legal and insurer requirements. The review frequency should reflect the site’s risk profile.

Which legal framework applies to fire risk in South African buildings?

The National Building Regulations and Building Standards Act and SANS 10400-T address building fire protection, while the Occupational Health and Safety Act and its regulations address workplace duties. Municipal by-laws, approved plans, occupancy conditions, insurer requirements and discipline-specific standards may also apply.

Who may sign a rational fire design or professional declaration?

Only a person who is appropriately competent and professionally authorised for the particular scope should accept that responsibility. The required category depends on the work, applicable regulation, local authority and identified engineering work.

How should findings be prioritised?

Immediate threats to life, blocked escape routes and critical system impairments should receive urgent attention. Remaining findings should be ranked by consequence, likelihood, legal or approval status, system dependency and the time and resources needed for correction.

11

Evacuation Plans

Emergency procedures, escape information, assembly arrangements and workplace preparedness.

Must every workplace have an evacuation plan?

Employers must provide safe means of egress and manage workplace emergencies under occupational health and safety requirements. The appropriate documented procedures, plans, appointments and drills depend on the building, occupancy, hazards and local requirements.

What information should an evacuation plan show?

It should clearly show the viewer’s location, escape routes, final exits, assembly area and relevant emergency equipment or information. Symbols should align with SANS 1186-1, while the routes and exits must correspond with the approved building layout and the escape provisions of SANS 10400-T.

Where should evacuation plans be displayed?

Plans should be positioned where occupants can readily see and use them, such as entrances, lift lobbies, common circulation areas and high-occupancy or higher-risk areas. Orientation, visibility and accessibility should be considered for each location.

How often should evacuation plans and procedures be updated?

Update them whenever layouts, exits, assembly areas, occupancy, hazards, emergency equipment or responsible people change. They should also be reviewed after drills, incidents or authority feedback and as part of the site’s scheduled emergency-preparedness review.

Are evacuation drills a legal substitute for compliant escape routes?

No. Drills test preparedness and reveal weaknesses, but they do not compensate for obstructed, inadequate or non-compliant exits. Escape doors, passages, stairs and final exits must remain available and effective whenever the premises are occupied.

12

Fire Protection Systems Practitioners (FPSPs)

ECSA registration, competence endorsements and professional oversight of fire-protection work.

What is an ECSA-registered Fire Protection Systems Practitioner?

An FPSP is registered by the Engineering Council of South Africa in a specified professional category after assessment of education, fire-engineering experience, discipline-specific competence and referee evidence. Under the Engineering Profession Act, a registered person may use the title Fire Protection Systems Practitioner and the abbreviation FPSP.

What work is covered by an FPSP’s registration?

Registration is endorsement-specific, not unlimited. Fire Brand’s professional oversight includes ECSA-endorsed competence as Designer, Installer, Commissioner, Maintainer and Inspector for sprinkler, high- and medium-velocity, foam, gaseous fire-suppression and fire-detection systems. The practitioner must work only within current endorsed competence.

What role does an FPSP have in assessing competent personnel?

An FPSP may assess whether personnel are competent for work within the practitioner’s endorsed scope, based on relevant experience and an appropriate examination or selection process. The practitioner remains responsible for exercising professional judgement and ensuring that assigned work is properly supervised and technically compliant.

Does a private inspection scheme have exclusive authority over FPSP competence?

No. ECSA is the statutory professional registration body, while a private rulebook or inspection scheme may impose additional technical or project requirements. A private company listing is not a substitute for ECSA registration and does not have exclusive authority to determine the professional competence of an ECSA-registered FPSP.

How should a client verify an FPSP’s authority and scope?

Request the practitioner’s ECSA registration number, confirm the current registration status and examine the relevant competence endorsements. The appointment should also define the systems, professional responsibilities, deliverables and any insurer, authority or project-specific acceptance conditions.

13

NFPA 25

Fire Brand’s application of inspection, testing, maintenance, tagging and recordkeeping requirements.

How does Fire Brand apply NFPA 25?

Fire Brand applies the relevant NFPA 25 inspection, testing and maintenance requirements where they are called for by the approved design, project requirements or relevant manufacturer instructions. NFPA 25 is applied alongside SANS 10287, applicable South African requirements, the approved design and OEM instructions rather than replacing them.

What do Fire Brand’s NFPA 25 tags show?

The dedicated tags identify the inspection, test or maintenance status, the person performing the work and the relevant date. They are system-maintenance records used with the detailed service report; they are not general-purpose labels or a stand-alone certificate of whole-system compliance.

What information should accompany an NFPA 25 maintenance tag?

The service record should identify the activity performed, results obtained, deficiencies or impairments found, relevant dates and any corrective action required. Conditions affecting system readiness should be reported to the client and, where applicable, the fire engineer, insurer or local authority.

Does a service tag prove OEM component traceability?

Not by itself. Maintenance tags and reports document work on the installed system, while OEM and distributor serial-number, batch and supply records establish product and service-kit traceability. Both record sets have distinct purposes and should be retained where applicable.

Must sprinkler valves and pumps carry a particular organisation’s branding?

The applicable rulebook, approved design or contract may require identification showing who performed the work and when an overhaul occurred. A general name-and-date tagging requirement does not automatically prescribe private-scheme branding. Any additional branding or tag format must come from an express insurer, contractual, project or scheme condition.

Authoritative reference points

Standards are revised and project requirements differ. Confirm the current edition and its application with the responsible professional and authority having jurisdiction.

Need an answer for your property?

Send us the project details and our team will help identify the applicable requirements and the right service scope.

Request Quotation